Các lỗi thường gặp

Code :
  • Code: C-0572
  • Description: PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper leading edge separation fan /Rr3 (FM12: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-F) 3. Replace FM12. 4. Replace PFUDB.
  • Code: C-0573
  • Description: PI-PFU (PF-703) paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper suction fan /1 (FM13: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 14-F) 3. Replace FM13 and PFUDB.
  • Code: C-0574
  • Description: PI-PFU (PF-703) paper suction fan /1 (FM13) rotation abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper suction fan /1 (FM13: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 14-F) 3. Replace FM13. 4. Replace PFUDB.
  • Code: C-0575
  • Description: PI-PFU (PF-703) paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper suction fan /3 (FM15: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM15 and PFUDB.
  • Code: C-0576
  • Description: PI-PFU (PF-703) paper suction fan /3 (FM15) rotation abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper suction fan /3 (FM15: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM15. 4. Replace PFUDB.
  • Code: C-0577
  • Description: PI-PFU (PF-703) paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper suction fan /5 (FM17: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L) 3. Replace FM17 and PFUDB.
  • Code: C-0578
  • Description: PI-PFU (PF-703) paper suction fan /5 (FM17) rotation abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper suction fan /5 (FM17: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L) 3. Replace FM17. 4. Replace PFUDB.
  • Code: C-0579
  • Description: PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper suction fan /2 (FM14: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 14-L) 3. Replace FM14 and PFUDB.