Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1050e — Trang 31/42

Code: SC53-07

Description: The blowout of a 5V fuse for the AC drive board (ACDB) is checked. In the serial initial communication, a signal of the blowout of a 5V fuse (AC drive) is detected.
Causes: AC drive board (ACDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-08

Description: The 12V power source in the printer control board (PRCB) is checked. An error detection signal of the 12V in the PRCB is detected.
Causes: DC power supply /1 (DCPS/ 1) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-11

Description: The blowout of a SD/CL fuse in the tray is detected 1. The 24V power source for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is also detected.
Causes: DC power supply /1 (DCPS/ 1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-12

Description: The blowout of a SD/CL fuse in the tray is detected 2. The blowout of a fuse for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected. However, an error detection signal (24V cut off) is not detected.
Causes: Paper feed clutch /1 (CL4), / 2 (CL6) Separation clutch /1 (CL5), / 2 (CL7) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-13

Description: The blowout of a fuse for the SD/ CL in the vertical conveyance is detected 1. The 24V power source for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/ clutch) is detected, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /1 (DCPS/ 1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-14

Description: The blowout of a fuse for the SD/ CL in the vertical conveyance is detected 2. The blowout of a fuse for the SD/CL in the printer control board (PRCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/ clutch) is detected. However, an error detection signal (24V cut off) is not detected.
Causes: Tray lock solenoid /1 (SD1), /2 (SD2), /3 (SD5) Drum claw solenoid (SD5) Pre-registration clutch /1 (CL1), /2 (CL3) Vertical conveyance clutch (CL2) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-15

Description: The blowout of a fuse for the SD/ CL in the PF is detected 1. The 24V power source for the SD/CL in the PF drive board (PFUCB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/clutch) is detected, and an error detection signal (24V cut off) is detected.
Causes: PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC53-16

Description: The blowout of a fuse for the SD/ CL in the PF is detected 2. The blowout of a fuse for the SD/CL in the PF drive board (PFUDB) is checked. At the start, an error detection signal (blowout of a fuse for the solenoid/motor) is detected. However, an error detection signal (24V cut off) is not detected.
Causes: PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).