Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1050e — Trang 37/42

Code: SC76-37

Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Fr (FM1) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /Fr (FM1) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC76-38

Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /1, /2 (FM2, FM6) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /1, /2 (FM2, FM6) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC76-39

Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Mi (FM3) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /Mi (FM3) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC76-40

Description: An error detection signal is detected for a specified period of time in succession while the motor cooling fan motor (FM4) of the tandem (2nd) LS is ON.
Causes: Motor cooling fan motor (FM4) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC76-41

Description: An error detection signal is detected for a specified period of time in succession while the paper cooling fan motor /Rr (FM5) of the tandem (2nd) LS is ON.
Causes: Paper cooling fan motor /Rr (FM5) LS control board (LSCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC77-01

Description: The conveyance motor (M1) operates for more than the allowed time at a speed out of the specified one.
Causes: FNS control board (FNSCB) FNS drive board (FNSDB) Conveyance motor (M1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC77-02

Description: The tray up down motor (M3) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one.
Causes: FNS control board (FNSCB) FNS drive board (FNSDB) Tray up down motor (M3) Tray upper limit sensor (PS2) Tray lower limit sensor (PS3)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC77-03

Description: The alignment home sensors /Rr (PS8) and /Fr (PS31) do not turn ON within a specified period of time after the home position search operation of the alignment motors /Rr (M5) and /Fr (M22) starts.
Causes: FNS control board (FNSCB) FNS drive board (FNSDB) Alignment motor /Rr (M5) Alignment motor /Fr (M22) Alignment home sensor /Rr (PS8) Alignment home sensor /Fr (PS31)
Remedy: The main body stops immediately to turn OFF the RL1 (main).