Description: Despite of the MPC not being terminated, the initial sampling of the APC is attempted.
Causes: Image processing board (IPB) Image processing program
Remedy: If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).
Code: SC46-32
Description: While executing the APC, the execution of the MPC is attempted.
Causes: Image processing board (IPB) Image processing program
Remedy: If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).
Code: SC46-35
Description: Sequentially shot page area abnormality. Due to an image area abnormality on the memory, images cannot be developed on the memory.
Causes: Image processing board (IPB) Image processing program
Remedy: If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).
Code: SC46-36
Description: Initial APC timing abnormality. The PVV is turned ON before the initial APC start processing is completed.
Causes: Write section Printer control program Image processing program
Remedy: If there is a copy being made, the main body completes the paper exit before stopping operations. Turn OFF the RL1 (main).
Code: SC46-40
Description: Hard disk initialization abnormality. The hard disk is defective, or the connector is poorly connected.
Causes: Image processing board (IPB) Image processing program Hard disk /1 (HDD1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC46-41
Description: The JOB information cannot be stored on the hard disk.
Causes: Image processing board (IPB) Image processing program Hard disk /1 (HDD1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC46-43
Description: Hard disk access defective. The hard disk is defective or the connector is connected improperly.
Causes: Image processing board (IPB) Image processing program Hard disk /1 (HDD1)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC46-61
Description: The scan operation starts before the original skew adjustment is terminated. (The skew adjustment is too late.)
Causes: ADF Original skew sensor /Fr (PS312), /Rr (PS311)
Remedy: Error codes are not displayed on the operation board, but displayed only on the data collection, the list output and the CSRC. The control of the main body is made by using a data previously obtained.