Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1050eP — Trang 28/42

Code: SC50-07

Description: Drive communication reception error detection abnormality
Causes: Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC50-08

Description: Drive communication reception error detection abnormality.
Causes: Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC50-10

Description: Initial communication check between the IC board (ICB)/printer control board (PRCB). Image processing board communication connection abnormality. An initial data is not received from the image processing board (IPB) within a specified period of time after the power is turned ON.
Causes: Overall control board (OACB) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC51-01

Description: Drive communication reception error detection abnormality.
Causes: Overall control board (OACB) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC51-02

Description: Drive communication reception error detection abnormality.
Causes: Printer control board (PRCB) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC51-03

Description: Drive communication reception error detection abnormality.
Causes: Printer control board (PRCB) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC52-01

Description: The rotation of the cooling fan /1 (FM1) is checked, and +24V power source is also checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after the FM1 turns ON. This abnormal condition recurs even a specified period of time after the FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).

Code: SC52-02

Description: The blowout of a fuse for the cooling fan /1 (FM1) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after the FM1 turns ON. This abnormal condition recurs even a specified period of time after the FM1 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected.
Causes: AC drive board (ACDB) Cooling fan /1 (FM1) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).