Description: The blowout of the sensor 5VICP is detected. An error detection signal of the blowout of the 5VICP is detected.
Causes: Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC53-18
Description: The fall-off of the erase lamp (EL) CN is detected. When turning ON the power, an error detection signal (fall-off) is detected a specified period of time after the fall-off detection control signal of the EL CN turns ON.
Causes: Erase lamp (EL)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC53-19
Description: An M5 EM error detection signal is detected twice in succession a specified period of time after the conveyance motor (M5) turns ON.
Causes: Conveyance motor (M5) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC53-20
Description: An M5 EM error detection signal is detected twice in succession a specified period of time after the ADU reverse/exit motor (M31) turns ON.
Causes: ADU reverse paper exit motor (M31) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC56-02
Description: The communication between the image processing board (IPB) and the operation board /1 (OB1) is checked. An initial communication from the main body to the operation board is not sent within 30 seconds after the power is turned ON.
Causes: Operation board /1 (OB1) Overall control board (OACB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC60-01
Description: Although the main body sent out data according to the data transmission request by the DF, the same request is received again.
Causes: Image processing board (IPB)
Remedy: If there is a copy being made, the main body and the DF complete the paper exit before stopping operations. Turn OFF the RL1 (main).
Code: SC60-02
Description: When a checksum error or an SRGA reception error was detected while in the reception in serial communication, a signal was sent to make a request for sending data again. And when data is being received upon this request, a checksum error or an SRGA reception error is detected again.
Causes: RADF control board (ADFCB)
Remedy: If there is a copy being made, the main body and the DF complete the paper exit before stopping operations. Turn OFF the RL1 (main).
Code: SC60-03
Description: When the main power switch (SW1) is ON, there is no response to the initial communication request from the main body to the DF even after a specified period of time elapses.
Causes: RADF control board (ADFCB)
Remedy: If there is a copy being made, the main body and the DF complete the paper exit before stopping operations. Turn OFF the RL1 (main).