Các lỗi thường gặp

Code :
  • Code: C-0353
  • Description: 1st tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) power abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5 and PFUDB at a time: PF-702 Replace FM9 and PFUDB at a time: PF-703
  • Code: C-0354
  • Description: 1st tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) rotation abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5: PF-702 Replace FM9: PF-703 - 4 Replace PFUDB.
  • Code: C-0356
  • Description: 1st tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) power abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703
  • Code: C-0357
  • Description: 1st tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) rotation abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6: PF-702 Replace FM10: PF-703 - 4 Replace PFUDB.
  • Code: C-0359
  • Description: 1st tandem PF-702/703 cooling fan power abnormality. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703
  • Code: C-0360
  • Description: 1st tandem PF-702/703 cooling fan rotation abnormality 1. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. However, an error detection signal (blowout of ICP) is not detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: PF cooling fan (FM7: PF-702) PF cooling fan/1 (FM19: PF-703) PF cooling fan /2 (FM20: PF-703) PF drive board (PFUDB: PF-702/703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7: PF-702 Replace FM19 and FM20: PF-703 - 4 Replace PFUDB.
  • Code: C-0361
  • Description: 1st tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: PF cooling fan /3 (FM21: PF-703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 23-F 3 Replace FM21 and PFUDB at a time.
  • Code: C-0370
  • Description: 2nd tandem PF-702/703 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1 and PFUDB.