Description: 2nd tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) rotation abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 18-F 3 Replace FM5: PF-702 Replace FM9: PF-703 - 4 Replace PFUDB.
Description: 2nd tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) power abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703
Description: 2nd tandem PF-702/703 paper feed assist fan /Rr3 (FM6: PF-702, FM10: PF-703) rotation abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6: PF-702 Replace FM10: PF-703 - 4 Replace PFUDB.
Description: 2nd tandem PF-702/703 cooling fan power abnormality. PF-702: The FM7EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703
Description: 2nd tandem PF-702/703 cooling fan rotation abnormality 1. PF-702: The FM20EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. However, an error detection signal (blowout of ICP) is not detected. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7: PF-702 Replace FM19 and FM20: PF-703 - 4 Replace PFUDB.
Description: 2nd tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 23-F 3 Replace FM21 and PFUDB at a time.
Description: PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1 and PFUDB.
Description: PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper feed assist fan /Fr1 (FM1: PF-702/703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and FM1, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair it if any abnormality. PF-702: 4-C PF-703: 6-F 3 Replace FM1. - 4 Replace PFUDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.