Code: C-0424

Description: Abnormality of the 12V power for the PF drive board (PFUDB) of PIPFU (PF-703). An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.

Code: C-0425

Description: Abnormality of the 24V power for the PF drive board (PFUDB) of PIPFU (PF-703). While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.

Code: C-0501

Description: 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 and PFUDB at a time.

Code: C-0502

Description: 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 - 4 Replace PFUDB.

Code: C-0503

Description: 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7 and PFUDB at a time.

Code: C-0504

Description: 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7. - 4 Replace PFUDB.

Code: C-0505

Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11 and PFUDB at a time.

Code: C-0506

Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11. - 4 Replace PFUDB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie