Description: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6 and PFUDB at a time: PF-702 Replace FM10 and PFUDB at a time: PF-703
Description: PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Paper feed assist fan /Rr3 (FM6: PF-703) Paper feed assist fan /Rr3 (FM10: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 9-C PF-703: 19-F 3 Replace FM6: PF-702 Replace FM10: PF-703 - 4 Replace PFUDB.
Description: PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7 and PFUDB at a time: PF-702 Replace FM19, FM20 and PFUDB at a time: PF-703
Description: PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 8-H PF-703: 22-F, 23-F 3 Replace FM7: PF-702 Replace FM19 and FM20: PF-703 - 4 Replace PFUDB.
Description: PI-PFU (PF-703) cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 23-F 3 Replace FM21 and PFUDB at a time.
Description: AC drive board (ACDB) 5V power abnormality. In the serial initial communication, a signal of the blowout of a 5VICP (AC drive) is detected.
Causes: AC drive board (ACDB) DC power supply /2 (DCPS /2)
Remedy: 1 Check the connector connection and the wiring on ACDB, and repair it if any abnormality. - 2 Replace ACDB. - 3 Replace DCPS /2.