Description: Apply roller high temperature abnormality (hardware detection) The glue apply roller temperature sensor (TH1) detects an abnormal high temperature. 35-5
Causes: Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: High temperature abnormality of the top of the glue tank (hardware detection) The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature. 35-5
Causes: Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: High temperature abnormality of the center of the glue tank (hardware detection) The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature. 35-5
Causes: Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: High temperature abnormality of the bottom of the glue tank (hardware detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature. 35-5
Causes: Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Apply roller low temperature abnormality (software detection) The glue apply roller temperature sensor (TH1) detects an abnormal low temperature. 35-5
Causes: Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Low temperature abnormality of the top of the glue tank (software detection) The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature. 35-5
Causes: Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Low temperature abnormality of the center of the glue tank (software detection) The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature. 35-5
Causes: Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Description: Low temperature abnormality of the bottom of the glue tank (software detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature. 35-5
Causes: Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.