Description: Apply roller low temperature abnormality (hardware detection) The glue apply roller temperature sensor (TH1) detects an abnormal low temperature. 35-5
Causes: Glue apply roller temperature sensor (TH1:PB-502, PB-503) Glue apply roller heater (H2:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue apply heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q, 9-U 5 Replace TH1. - 6 Replace H2. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Code: C-1560
Description: Low temperature abnormality of the top of the glue tank (hardware detection) The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature. 35-5
Causes: Glue tank temperature sensor /Up (TH2:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 9-W PB-503: 27-Q 9-U 5 Replace TH2. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Code: C-1561
Description: Low temperature abnormality of the center of the glue tank (hardware detection) The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature. 35-5
Causes: Glue tank temperature sensor /Md (TH3:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH3. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Code: C-1562
Description: Low temperature abnormality of the bottom of the glue tank (hardware detection) The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature. 35-5
Causes: Glue tank temperature sensor /Lw (TH4:PB-502, PB-503) Glue tank heater (H1:PB-502, PB-503) PB control board (PBCB: PB-502, PB-503) AC drive board (ACDB: PB-502, PB-503)
Remedy: 1 Check the glue tank heater, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBCB and the temperature sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and the heater, and repair it if any abnormality. - 4 Check the installation conditions of the heater and the temperature sensor, and repair/replace it if any abnormality. PB-502: 27-V, 10-W PB-503: 27-Q, 10-U 5 Replace TH4. - 6 Replace H1. - 7 Replace ACDB. - 8 Replace PBCB. - *After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. If DipSW3-1 is set to 0 before defective parts are fixed, it causes fire.
Code: C-1565
Description: PB-503: Operation abnormality of the relay conveyance motor (M92) The relay conveyance does not start within the specified period of time after M92 turns ON. 35-4
Causes: Intermediate conveyance motor (M92: PB-503) PB drive board /2 (PBDB2: PB-503) PB control board (PBCB: PB-503)
Remedy: 1 Check the relay conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 23-V 4 Replace M92. - 5 Replace PBDB2. - 6 Replace PBCB.
Code: C-1566
Description: PB-503: Operation abnormality of the relay conveyance exit motor (M91) An error detection signal is detected continuously while the M91 is driving. 35-4
Remedy: 1 Check the relay conveyance paper exit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 26-W 5 Replace M91. - 6 Replace PBDB2. - 7 Replace PBDB1. - 8 Replace PBCB. -
Code: C-1567
Description: PB-503: Operation abnormality of the pellet supply pipe motor (M33). The pellet supply pipe does not complete the operation within the specified period of time after M33 turns ON. 35-4
Causes: Pellet supply pipe motor (M33: PB-503) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-503)
Remedy: 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB1 and the motor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-503: 10-D 4 Replace M33. - 5 Replace PBDB1. - 6 Replace PBCB.
Code: C-2101
Description: Charger cleaning motor (M23) operation time abnormality. • When the charger cleaning home sensor (PS26) is OFF with the main power switch (SW1) ON, PS26 does not turn ON within 35seconds after the M23 turns ON for home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. • PS26 does not turn OFF within 15seconds after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. • The charge cleaning limit sensor (PS27) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS26 being OFF. Or, PS26 does not turn ON within a specified period of time after PS27 turns ON. At this time, an error detection signal (blowout of ICP) is not detected. • When PS26 and PS27 are ON at the start of cleaning operation
Causes: Charger cleaning home sensor (PS26) Charger cleaning limit sensor (PS27) Charger cleaning motor (M23) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 16-F 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 16-F 4 Replace PS26 or PS27. - 5 Replace M23. - 6 Replace PRCB.