Description: ADU drive board (ADUDB) power abnormality 1. An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. At this time, an error detection signal (24V cut off) is detected.
Causes: ADU drive board /1 (ADUDB1) DC power supply /1 (DCPS/1)
Remedy: 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB1 and DCPS /1, and repair it if any abnormality. - 3 Replace ADUDB1. - 4 Replace DCPS /1.
Description: ADU drive board (ADUDB) power abnormality 2. An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. However, an error detection signal (24V cut off) is not detected.
Remedy: 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB1 and sensor/solenoid, and repair it if any abnormality. 17-L, 18-O 3 Check the drive and the coupling of the sensor and the solenoid, and repair it if any abnormality. - 2 Replace ADUDB1.
Description: Interlock power abnormality of the ADU drive board (ADUDB). An error signal of the 24V interlock power is detected in the door detection closed status.
Causes: ADU drive board /1 (ADUDB1) DC power supply /3 (DCPS /3)
Remedy: 1 Check the connector connection and the wiring on ADUDB1, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB1 and DCPS /3, and repair it if any abnormality. - 3 Replace ADUDB1. - 4 Replace DCPS /3.
Description: Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.
Description: Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.
Description: Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-702/703. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.
Description: Abnormality of the 24V power for the PF drive board (PFUDB) of the 2nd tandem PF-702/703. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
Causes: PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.