Description: HDD/1 (HDD1) access defective. HDD1 is defective, or the connector is poorly connected.
Causes: Hard disk /1 (HDD1) Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1.
Description: Message queue error. The message queue is insufficient or destroyed.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
Description: Message parameter value error. The parameter value is in excess of the permissible limits.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
Description: Source task error. The ID of the task that sends the message queue is undefined.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
Description: Receiving event error. The receiving event of the message is undefined.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.