Các lỗi thường gặp

Code :
  • Code: C-1146
  • Description: Bypass roller release motor (M12) drive abnormality. The bypass roller release home sensor (PS13) does not turn ON even after a specified period of time after M12 starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. 35-1
  • Causes: Bypass roller release home sensor (PS13: FS-521) Bypass roller release motor (M12: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
  • Remedy: 1 Check the bypass roller section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 5-C 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 4-B 6 Replace PS13. - 7 Replace M12. - 8 Replace FNSDB. - 9 Replace FNSCB.
  • Code: C-1147
  • Description: Paper exit alignment plate retraction motor (M18) drive abnormality. The paper exit alignment plate home sensor (PS24) does not turn ON even after a specified period of time after M18 starts the home position search operation. Or, even after a specified period of time after M18 starts the operation, it does not stop. 35-1
  • Causes: Paper exit alignment plate retraction home sensor (PS24: FS-521) Paper exit alignment plate retraction motor (M18: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
  • Remedy: 1 Check the paper exit alignment retraction section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 7-M 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 4-G 6 Replace PS24. - 7 Replace M18. - 8 Replace FNSDB. - 9 Replace FNSCB.
  • Code: C-1148
  • Description: Stacker entrance roller release motor (M16) drive abnormality. The stacker entrance roller release home sensor (PS23) does not turn ON even after a specified period of time after M16 starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop. 35-1
  • Causes: Stacker entrance roller release home sensor (PS23: FS-521) Stacker entrance roller release motor (M16: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
  • Remedy: 1 Check the stacker entrance roller release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 6-G 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FS-521: 6-G 6 Replace PS23. - 7 Replace M16. - 8 Replace FNSDB. - 9 Replace FNSCB.
  • Code: C-1201
  • Description: 1st tandem LS-505 stacker tray up down motor (M1) drive abnormality. The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after M1 turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. 33-6
  • Causes: Stacker tray encoder sensor (PS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-A 5 Replace PS2. - 6 Replace M1. - 7 Replace LSCB.
  • Code: C-1202
  • Description: 1st tandem LS-505 shift unit motor (M5) drive abnormality. The shift unit home sensor (PS11) does not turn OFF within a specified period of time after M5 turns ON. Or, PS11 does not turn ON within a specified period of time. 33-6
  • Causes: Shift unit home sensor (PS11: LS-505) Shift unit motor (M5: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the shift unit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS11. - 6 Replace M5. - 7 Replace LSCB.
  • Code: C-1203
  • Description: 1st tandem LS-505 alignment motor (M7) drive abnormality. The alignment plate home sensor (PS12) does not turn ON within a specified period of time after M7 turns ON. Or, PS12 does not turn ON within a specified period of time. 33-6
  • Causes: Alignment plate home sensor (PS12: LS-505) Alignment motor (M7: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 7-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS12. - 6 Replace M7. - 7 Replace LSCB.
  • Code: C-1204
  • Description: 1st tandem LS-505 grip conveyance motor (M4) drive abnormality. The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after M4 turns ON. 33-6
  • Causes: Grip conveyance home sensor (PS5: LS-505) Grip conveyance motor (M4: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the grip conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 2-H 5 Replace PS5. - 6 Replace M4. - 7 Replace LSCB.
  • Code: C-1205
  • Description: 1st tandem LS-505 stacker tray upper limit abnormality. The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. 33-6
  • Causes: Stacker tray upper limit switch (MS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS2. - 6 Replace M1. - 7 Replace LSCB.