Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.
Description: 5V power abnormality in the SD drive board (SDDB).
Causes: SD drive board (SDDB) SD control board (SDCB)
Remedy: 1 Check the connector connection and the wiring of SDDB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 3 Replace SDDB - 4 Replace SDCB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of FDCB, and repair it if any abnormality. - 3 Reinstalling FD firmware - 4 Replace FDCB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of SDCB, and repair it if any abnormality. - 3 Reinstalling SD firmware - 4 Replace SDCB.
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of RUCB, and repair it if any abnormality. - 3 Reinstalling RU firmware - 4 Replace RUCB
Description: PB control board (PBCB) error 1. Message queue full or the control abnormality of Sub CPU1 in PBCB.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.
Description: PB control board (PBCB) error 2. Message queue full or the control abnormality of Sub CPU2 in PBCB.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.
Description: PB control board (PBCB) error 3. Message queue of the communication among tasks in the PB is full.
Causes: PB control board (PBCB: PB-502, PB-503)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the all power plugs. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring of PBCB, and repair it if any abnormality. - 3 Reinstalling PB firmware - 4 Replace PBCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.