  • Code: C-0424
  • Description: Abnormality of the 12V power for the PF drive board (PFUDB) of PIPFU (PF-703). An error detection signal of the PFUDB (blowout of 12V ICP) is detected.
  • Causes: PF drive board (PFUDB: PF-702/703)
  • Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.
  • Code: C-0425
  • Description: Abnormality of the 24V power for the PF drive board (PFUDB) of PIPFU (PF-703). While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.
  • Causes: PF drive board (PFUDB: PF-702/703)
  • Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Replace PFUDB.
  • Code: C-0501
  • Description: 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 and PFUDB at a time.
  • Code: C-0502
  • Description: 1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: Paper leading edge separation fan /Fr1 (FM3: PF- 703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 6-F 3 Replace FM3 - 4 Replace PFUDB.
  • Code: C-0503
  • Description: 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7 and PFUDB at a time.
  • Code: C-0504
  • Description: 1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: Paper leading edge separation fan /Fr2 (FM7: PF- 703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 11-F 3 Replace FM7. - 4 Replace PFUDB.
  • Code: C-0505
  • Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11 and PFUDB at a time.
  • Code: C-0506
  • Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: Paper leading edge separation fan /Fr3 (FM11: PF- 703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-703: 19-F 3 Replace FM11. - 4 Replace PFUDB.