Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1200P — Trang 90/91

Code: C-D004

Description: HDD/1 (HDD1) access defective. HDD1 is defective, or the connector is poorly connected.
Causes: Hard disk /1 (HDD1) Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 1 Check the connector connection and the wiring between OACB and HDD1, and repair it if any abnormality. 4-D 2 Reinstall the firmware related to the overall control. - 3 Replace HDD1.

Code: C-D010

Description: Hard disk /1 (HDD1) overwrite erase execution. HDD overwrite erase is executed.
Causes: Hard disk /1 (HDD1)
Remedy: 1 Format HDD1. - 2 Replace HDD1.

Code: C-E001

Description: Message queue error. The message queue is insufficient or destroyed.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.

Code: C-E002

Description: Message parameter value error. The parameter value is in excess of the permissible limits.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.

Code: C-E003

Description: Source task error. The ID of the task that sends the message queue is undefined.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.

Code: C-E004

Description: Receiving event error. The receiving event of the message is undefined.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.

Code: C-E005

Description: Memory access abnormality.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.

Code: C-E006

Description: Header readout address abnormality.
Causes: Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Reinstall the firmware related to the overall control. - 3 Replace OACB.