Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub Pro 1200P — Trang 36/91

Code: C-0660

Description: 2nd tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB.

Code: C-0661

Description: 2nd tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB.

Code: C-0662

Description: 2nd tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.
Causes: Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connection between ACDB/2 and the noise filter of PF-703. - 2 Check the connector connection and the wiring between ACDB /2 and the fun heater, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 4 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 5 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 6 Replace the fun heater. - 7 Replace ACDB/2. - 8 Replace PFUDB.

Code: C-0671

Description: PI-PFU (PF-703) dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal.
Causes: Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB.

Code: C-0672

Description: PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal.
Causes: Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB.

Code: C-0673

Description: PI-PFU (PF-703) dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal.
Causes: Lower tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB.

Code: C-0674

Description: PI-PFU (PF-703) dehumidification heater /1 (HTR1) high temperature software abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C.
Causes: Upper tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB.

Code: C-0675

Description: PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C.
Causes: Middle tray fan heater (HT-505) AC drive board /2 (ACDB/2: HT-505) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun heater, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and ACDB /2, and repair it if any abnormality. - 3 Check the temperature and the installation of the fan heater, and repair it if any abnormality. - 4 Replace the fun heater. - 5 Replace ACDB/2. - 6 Replace PFUDB.