Description: 2nd folding release motor (M15) drive abnormality. The 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time after M15 turns ON. 33-0
Causes: 2nd folding cam home sensor (PS56: FD-503) 2nd folding release motor (M15: FD-503) Folding drive board (FDB: FD-503)
Remedy: 1 Check the 2nd folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS56. - 6 Replace M15. - 7 Replace FDB.
Code: C-1223
Description: 3rd folding release motor (M16) drive abnormality. The 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time after M16 turns ON. 33-0
Causes: 3rd folding cam home sensor (PS57: FD-503) 3rd folding release motor (M16: FD-503) Folding drive board (FDB: FD-503)
Remedy: 1 Check the 3rd folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS57. - 6 Replace M16. - 7 Replace FDB.
Code: C-1224
Description: 2-hole operation abnormality. The 2-holes punch home sensor (PS8) does not turn OFF within a specified period of time after the 2-holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2- holes punch home sensor (PS8) does not turn OFF. 33-0
Causes: 2 holes punch home sensor (PS8: FD-503) Punch motor (M10: FD-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the 2-hole punch section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS8. - 6 Replace M10. - 7 Replace PDB.
Code: C-1225
Description: 3-hole/4-hole punch operation abnormality. The 3 holes/4 holes punch home sensor (PS9) does not turn OFF within a specified period of time after the 3 holes/4 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 3 holes/4 holes punch home sensor (PS9) does not turn OFF. 33-0
Causes: 3 holes/4 holes punch home sensor (PS9: FD-503) Punch motor (M10: FD-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the 3-hole/4-hole punch section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS9. - 6 Replace M10. - 7 Replace PDB.
Code: C-1226
Description: Punch alignment plate operation abnormality. The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF. 33-0
Causes: Alignment plate home sensor (PS10: FD-503) Alignment motor (M12: FD-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-D 5 Replace PS10. - 6 Replace M12. - 7 Replace PDB.
Code: C-1227
Description: Punch paper trailing edge operation abnormality. The punch registration home sensor (PS11) does not turn ON within a specified period of time after the punch registration claw home position return operation starts. Or, after the punch registration motor (M13) turns ON, the punch registration home sensor (PS11) does not turn OFF. 33-0
Causes: Punch registration home sensor (PS11: FD-503) Punch registration motor (M13: FD-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS11. - 6 Replace M13. - 7 Replace PDB.
Code: C-1228
Description: Exit tray operation abnormality 1. The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF. 33-2
Causes: Main tray upper limit sensor (PS20: FD-503) Tray up down motor (M11: FS-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 6-D 5 Replace PS20. - 6 Replace M11. - 7 Replace PDB.
Code: C-1229
Description: Exit tray operation abnormality 2. The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation. 33-2
Causes: Main tray lower limit sensor (PS22: FD-503) Tray up down motor (M11: FS-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 3-D 5 Replace PS22. - 6 Replace M11. - 7 Replace PDB.