Code: C-5342

Description: Collection pipe cooling fan (FM34) power abnormality. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Collection pipe cooling fan (FM34) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 3 Replace FM34 and PRCB at a time.

Code: C-5343

Description: Collection pipe cooling fan (FM34) rotation abnormality 1. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Collection pipe cooling fan (FM34) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 3 Replace FM34. - 4 Replace PRCB.

Code: C-5344

Description: Collection pipe cooling fan (FM34) rotation abnormality 2. When the print is started, the EM signal of FM34 turns ON.
Causes: Collection pipe cooling fan (FM34) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 1-L 3 Replace FM34. - 4 Replace PRCB.

Code: C-5345

Description: Toner bottle cooling fan (FM35) rotation abnormality + 24V power abnormality. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.

Code: C-5346

Description: Toner bottle cooling fan (FM35) power abnormality. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Toner bottle cooling fan (FM35) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM35 and ACDB at a time.

Code: C-5347

Description: Toner bottle cooling fan (FM35) rotation abnormality 1. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Toner bottle cooling fan (FM35) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM35. - 4 Replace PRCB.

Code: C-5348

Description: Toner bottle cooling fan (FM35) rotation abnormality 2. When the print is started, the EM signal of FM35 turns ON.
Causes: Toner bottle cooling fan (FM35) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM35. - 4 Replace PRCB.

Code: C-5349

Description: DC power supply /3 cooling fan (FM36) rotation abnormality + 24V power abnormality The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. At this time, an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS /2) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace ACDB.