Description: 1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11. - 4 Replace PFUDB.
Code: C-0264
Description: 1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11 and PFUDB at a time.
Code: C-0265
Description: 1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12. - 4 Replace PFUDB.
Code: C-0266
Description: 1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 19-L 3 Replace M12 and PFUDB at a time.
Code: C-0271
Description: 2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10. - 4 Replace PFUDB.
Code: C-0272
Description: 2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10 and PFUDB at a time.
Code: C-0273
Description: 2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11. - 4 Replace PFUDB.
Code: C-0274
Description: 2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 17-L 3 Replace M11 and PFUDB at a time.