Description: Rotation of the cooling fan /1 (FM3) and /2 (FM4) are checked. An abnormal condition occurs with the FM3 and FM4 EM signal a specified period of time after FM3 and FM4 turns ON. This abnormal condition recurs even a specified period of time after FM3 and FM4 are turned OFF and then turned ON, and an error detection signal (24V cut off) is not detected.
Causes: AC drive board (ACDB) Printer control board (PRCB) Cooling fan /1 (FM3) Cooling fan /2 (FM4) Loose connection
Description: The blowout of ICP for the cooling fan /1 (FM3) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM3 EM signal a specified period of time after FM3 turns ON. This abnormal condition recurs even a specified period of time after FM3 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: AC drive board (ACDB) Cooling fan /1 (FM3) Wiring harness earth fault
Description: Rotation of the cooling fan /1 (FM3) is checked. An abnormal condition occurs with the FM3 EM signal a specified period of time after FM3 turns ON. This abnormal condition recurs even a specified period of time after FM3 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is not detected.
Causes: AC drive board (ACDB) Cooling fan /1 (FM3) Loose connection
Description: The blowout of ICP for the cooling fan /2 (FM4) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 turns ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: AC drive board (ACDB) Cooling fan /2 (FM4) Wiring harness earth fault
Description: Rotation of the cooling fan /2 (FM4) is checked. An abnormal condition occurs with the FM4 EM signal a specified period of time after FM4 turns ON. This abnormal condition recurs even a specified period of time after FM4 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is not detected.
Causes: AC drive board (ACDB) Cooling fan /2 (FM4) Wiring harness earth fault
Description: The rotation of the cooling fan /3 (FM6) is checked and +24V power source is also checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: AC drive board (ACDB) Cooling fan /3 (FM6) Wiring harness earth fault Loose connection DC power supply /2 (DCPS2)
Description: The blowout of ICP for the cooling fan /3 (FM6) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (blowout of ICP) is detected.
Causes: AC drive board (ACDB) Cooling fan /3 (FM6) Wiring harness earth fault Loose connection DC power supply /2 (DCPS2)
Description: Rotation of the cooling fan /3 (FM6) is checked. An abnormal condition occurs with the FM6 EM signal a specified period of time after FM6 turns ON. This abnormal condition recurs even a specified period of time after FM6 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of ICP) is not detected.
Causes: AC drive board (ACDB) Cooling fan /3 (FM6) Wiring harness earth fault Loose connection DC power supply /2 (DCPS2)
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.