Các lỗi thường gặp

Code :
  • Code: SC32-06
  • Description: The rotation of the fusing fan (FM1) is checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after FM1 is turned ON. This abnormal condition recurs even a specified period of time after FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off/ blowout of ICP) is not detected.
  • Causes: ADU drive board (ADUDB) Fusing fan (FM1) DC power supply /2 (DCPS2) Loose connection
  • Code: SC32-07#
  • Description: When the print is completed, the fusing fan (FM1) EM signal gets into an abnormal condition.
  • Causes: ADU drive board (ADUDB) Fusing fan (FM1) DC power supply /2 (DCPS2) Loose connection
  • Code: SC33-01
  • Description: Registration motor (M12) speed abnormality. A specified period of time after M12 turns ON, an error detection signal is detected twice in a row. (An error detection signal on the first time is ignored.)
  • Causes: Registration motor (M12) Loose connection
  • Code: SC33-05
  • Description: The blowout of ICP for the web motor (M16) in the printer control board (PRCB) is checked, and the 24V power source is also checked. When M16 turn ON from OFF, error detection signals (blowout of ICP and the 24V cut off) are detected.
  • Causes: DC power supply /2 (DCPS2) Printer control board (PRCB)
  • Code: SC33-06
  • Description: The blowout of ICP for the web motor (M16) in the printer control board (PRCB) is checked. When M16 turns ON from OFF, the blowout of ICP abnormality is detected with a 24V down signal normal.
  • Causes: Web motor (M16) Printer control board (PRCB) AC drive board (ACDB)
  • Code: SC34-01
  • Description: Thermistor /1 (TH1) high temperature detection (software). TH1 detects a temperature of 210°C or above 5 times in a specified period of time.
  • Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /3 (TH3)
  • Code: SC34-02
  • Description: Thermistor /3 (TH3) high temperature detection (software). TH3 detects a temperature of 230°C or above 5 times in a specified period of time.
  • Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /3 (TH3)
  • Code: SC34-03
  • Description: Thermistor /1 (TH1) high temperature detection (hardware). An abnormal condition is detected with the fusing error detection signal 1.
  • Causes: Printer control board (PRCB) AC drive board (ACDB) Fusing heater lamp /1 (L2) Fusing heater lamp /2 (L3) Fusing heater lamp /3 (L4) Thermistor /1 (TH1) Thermistor /3 (TH3)