Description: After the punch switching motor (M8) starts the home position search, the punch switching switch (MS2) does not turn ON even when a specified period of time elapses.
Causes: Confirmation of the wiring harness and the connector Confirmation of the punch switchover drive parts Punch switchover switch (MS2) Punch switchover motor (M8) ZU control board (ZUCB)
Code: C-1181
Description: After the gate motor (M12) starts the home position search, the gate home sensor (PS16) does not turn ON even when a specified period of time elapses.
Causes: Confirmation of the wiring harness and the connector Confirmation of the gate drive parts Gate home sensor (PS16) Gate motor (M12) FS control board (FSCB)
Code: C-1356
Description: A specified period of time after the conveyance motor cooling fan (M10) is turned on, the EM signal of the M10 gets into an abnormal condition.
Causes: Confirmation of the wiring harness and the connector Conveyance motor cooling fan (M10) ZU control board (ZUCB)
Code: C-2101
Description: When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the charge cleaning motor (M23) turns ON for home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. It is checked that the time for the M23 operations is over. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON.
Causes: Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB)
Code: C-2102
Description: The blowout of ICP for the charge cleaning motor (M23) in the printer control board (PRCB) is checked. When the charge cleaning home sensor (PS41) is OFF with the main power switch (SW1) ON, PS41 does not turn ON within a specified period of time after the M23 turns ON for home position research operation (return operation). And at this time, an error detection signal (blowout of ICP) is detected. PS41 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. And at this time, an error detection signal (blowout of ICP) is detected. The charge cleaning limit sensor (PS42) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS41 being OFF. Or, PS41 does not turn ON within a specified period of time after PS42 turns ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB)
Code: C-2103
Description: The locking of the charge cleaning motor (M23) is detected. A motor lock signal is detected while moving from the charge cleaning limit sensor (PS42) side to the charge cleaning home sensor (PS41) side, and after a retry operation, a fifth motor lock signal is detected.
Causes: Confirming the operation of the charging corona cleaning member Confirmation of the wiring harness and the connector Charge cleaning motor (M23) Charge cleaning home sensor (PS41) Charge cleaning limit sensor (PS42) Printer control board (PRCB)
Code: C-2104
Description: It is checked that the operations of the transfer/separation cleaning motor (M18) are over. When the transfer/separation cleaning home sensor (PS11) is OFF with the main power switch (SW1) ON, PS11 does not turn ON within a specified period of time after the M18 turns ON for a home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. PS11 does not turn OFF within a specified period of time after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. It is checked that the operations of the M18 are over. The transfer/ separation cleaning limit sensor (PS12) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS11 being OFF. Or, PS11 does not turn ON within a specified period of time after PS12 turns ON. At this time, an error detection signal (blowout of ICP) is not detected.
Causes: Confirmation of the wiring harness and the connector Transfer/separation cleaning motor (M18) Transfer/separation cleaning home sensor (PS11) Transfer/separation cleaning limit sensor (PS12) ADU drive board (ADUDB)
Code: C-2106
Description: The locking of the transfer/separation cleaning motor (M18) is detected. Motor lock signals are detected while moving from the transfer/separation limit sensor (PS12) side to the transfer/separation home sensor (PS11) side, and after a retry operation, a fifth motor lock signal is detected.
Causes: Confirmation of the transfer/ separation cleaning member Confirmation of the wiring harness and the connector Transfer/separation cleaning motor (M18) Transfer/separation cleaning home sensor (PS11) Transfer/separation cleaning limit sensor (PS12) ADU drive board (ADUDB)