Code: C0B4E

Description: Finisher Tray Motor drive malfunction
Remedy:

Code: C0B50

Description: Stapling Motor 1 drive malfunction / Stapling Motor drive malfunction
Remedy:

Code: C0B54

Description: Stapling Motor 2 drive malfunction
Remedy:

Code: C0B73

Description: Punch Motor drive malfunction
Remedy:

Code: C0B78

Description: Hole Position Selector Motor drive malfunction (U.S.A. and Canada)
Remedy:

Code: C0B80

Description: Shift Motor drive malfunction
Remedy:

Code: C0BA0

Description: Elevator Motor drive malfunction
Remedy:

Code: C0F32

Description: Faulty ATDC Sensor
The value of data read by the ATDC Sensor is faulty. (ATDC Sensor reading is 19 % or more, or 7 % or less.)
Remedy: 1 ATDC Sensor and Master Board are connected properly. NO Correct connection. 2 The voltage across PJ6PU1-5 on Power Supply Unit and GND is DC5 V. YES Change I/C. Change Master Board. NO Change Power Supply Unit.