Mã lỗi Konica-Minolta Di551 — Trang 3/22

Code: E46-23

Description: Image control abnormality
During image read, SVV is not turned OFF within the specified time and therefore preparation for next page scanning cannot be started.
Causes: PRCB (printer control board) ICB (image control board) ICB program

Code: E46-24

Description: Image control abnormality
Shading correction error (GA error)
Causes: ICB (image control board) ICB program

Code: E46-25

Description: Image control abnormality
AOC/AGC error • The light blocking cover and lens cover are removed from the scanner section. • The A/D converter board connector is disconnected. • The power cable of A/D converter board is disconnected. • The IC protector on the A/D converter board is blown out. • The exposure lamp intensity is excessive. • The exposure lamp does not light.
Causes: ADB (A/D conversion board) L1 (exposure lamp)

Code: E46-26

Description: Image control abnormality
Correction data saved on a resolution basis is not found.
Causes: ICB (image control board)

Code: E46-27

Description: Image control abnormality
The density correction γ curve cannot be generated properly.
Causes: ICB (image control board)

Code: E46-29

Description: Image control abnormality
Calibration start error.
Causes: ICB (image control board) ICB program

Code: E46-30

Description: Image control abnormality
Calibration end error
Causes: ICB (image control board) ICB program

Code: E46-31

Description: Image control abnormality
An attempt was made to perform APC initial sampling before completion of MPC.
Causes: ICB (image control board) ICB program