Các lỗi thường gặp

Code :
  • Code: F46-42
  • Description: Image control abnormality
    A route could not be opened during hard disk job automatic deletion.
  • Causes: ICB (image control board) ICB program HDD (hard disk drive)
  • Code: F46-43
  • Description: Image control abnormality
    Hard disk access failure Hard disk failure or poor connection of connectors
  • Causes: ICB (image control board) ICB program HDD (hard disk drive)
  • Code: F46-50
  • Description: Image control abnormality
    Communication error is detected during the tandem operation.
  • Causes: ICB (image control board) ICB program Around the tandem cable
  • Code: F46-51
  • Description: Image control abnormality
    An error is detected during the data transfer of tandem image.
  • Causes: ICB (image control board) ICB program Around the tandem cable
  • Code: F46-60
  • Description: Image control abnormality
    Adjustment of the sub-scan beam interval is not completed within the specified number of time for the following reason: • Defective index sensor • Abnormal 12 VDC power supply • M15 (polygon) driving failure
  • Causes: Write section
  • Code: F46-61
  • Description: Image control abnormality
    Scanning started before completion of original auto skew correction. (Skew correction was not in time).
  • Causes: PRCB (printer control board) PS311 (original mis-centering /F) PS311 (original mis-centering /R)
  • Code: F46-62
  • Description: Image control abnormality
    Printing started before correction of auto paper mis-centering. (Mis-centering correction was not in time).
  • Causes: PS1 (paper mis-centering detection PS)
  • Code: F46-63
  • Description: Image control abnormality
    AGC was retried because of reduction in exposure lamp intensity, but no error occurred.
  • Causes: L1 (exposure lamp)