Description: Image control abnormality
The PWM γ curve could not be generated properly.
Causes: TCSB (toner control sensor board)
Code: F52-01
Description: Fan abnormality
FM13 (power supply cooling) EM signal was abnormal 2 seconds after turning ON FM13. 2 seconds after turning FM13 OFF and ON again, the signal is still abnormal.
Causes: FM13 (power supply cooling) DCPS (DC power supply unit)
Code: F52-02
Description: Fan abnormality
The MAINFAN_EM signal was abnormal 2 seconds after turning ON FM1 (main body cooling /1). 2 seconds after turning OFF and ON again, the signal is still abnormal.
Causes: FM1 (main body cooling /1) PRCB (printer control board)
Code: F53-01
Description: Motor abnormality
5 seconds or later after turning ON M4 (fixing), an abnormal MAINM_EM signal has been detected for 1 consecutive second.
Causes: M4 (fixing) PRCB (printer control board)
Code: F62-01
Description: Fan Abnormality
FM301 (original conveyance motor cooling) EM signal was abnormal 2 seconds after turning ON FM301. 2 seconds after turning FM301 OFF and ON again, an abnormal detection signal is detected.
Causes: SCDB (scanner drive board) FM301 (original conveyance motor cooling)
Code: F77-1
Description: (FN-112/ 6/121/10/ 115) After M702 (shift) starts operation, the shift unit does not reach the shift position or the HP within the specified time.
Causes: FNSCB (FNS control board) M702 (shift) PS718 (shift HP)
Code: F77-1
Description: (OT-104) PS702 (shift HP) does not turn ON within the predefined time after M703 (shift) starts operation.
Causes: SFCB (SF control board) M703 (shift) PS702 (shift HP)
Code: F77-11
Description: FN-112/6/ 121/10/115 abnormality
(FN-112/ 6/121/10) After M714 (stapler /F) starts operation, PS731 (stapler HP/F) does not turn ON within the specified time.