Description: High-voltage power error
5 consecutive charging ON/OFF operations have been executed since the charging error detection signal has been detected while charging is turned ON.
Description: High-voltage power error
5 consecutive transfer ON/OFF operations have been executed since the transfer error detection signal has been detected while transfer is turned ON.
Description: High-voltage power error
5 consecutive separation ON/OFF operations have been executed since the separation error detection signal has been detected while separation is turned ON.
Description: Process abnormality
Dirt correction failure of the Dmax sensor during maximum density adjustment. If this error is detected 10 successive times, the error code is displayed.
Causes: TSCB (toner control sensor board) PRCB (printer control board)