Description: Process abnormality
Dirt correction failure of the γ sensor during γ adjustment. If this error is detected 10 successive times, the error code is displayed.
Causes: TSCB (toner control sensor board) PRCB (printer control board)
Description: Process abnormality
Dirt correction failure of the γ sensor during dot diameter adjustment. If this error is detected 10 successive times, the corresponding error code is displayed.
Causes: TSCB (toner control sensor board) PRCB (printer control board)
Description: Fan abnormality
An error for SUC_EM signal is detected when 2 seconds have passed since FM3 (conveyance suction) has turned ON. The error does not clear after 2 seconds from the OFF/ON operation.
Description: Fan abnormality
An error for FIXFAN1_EM signal is detected when 2 seconds have passed since FM8 (main unit cooling / 2) has turned ON. The error does not clear after 2 seconds from the OFF/ON operation.
Causes: FM8 (main cooling /2) PRCB (printer control board)
Description: Fan abnormality
An error for FIXFAN3_EM signal is detected when 2 seconds have passed since FM6 (paper exit fan /F) has turned ON. The error does not clear after 2 seconds from OFF/ON operation.
Causes: FM6 (paper exit fan /F) PRCB (printer control board)