Code: 04H

Description: Printer control board malfunction
• Communications with the M/C expansion IO G/A (IC on the printer control board) are not properly carried out.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change PRCB.

Code: 05H

Description: Flash ROM malfunction
• Engine firmware upgrading has failed.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change PRCB.

Code: 08H

Description: Main motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the main motor remains energized. • The motor lock signal remains LOW for a predetermined consecutive period of time while the main motor remains deenergized.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check. PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) C-4. 5 Change PRCB. 6 Change DCPU1.

Code: 0BH

Description: Ventilation fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the ventilation fan motor remains energized.
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. 2 Check FM2 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 FM2 operation check. PRCB PJ10PRCB-1 (REM) PECB PJ10PRCB-3 (LOCK) C-4. 5 Change PRCB. 6 Change DCPU1.

Code: 0CH

Description: Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized.
Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check FM1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check. PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCB-3 (LOCK) C-2. 5 Change PRCB. 6 Change DCPU1.

Code: 0FH

Description: Duplex cooling fan motor malfunction
Remedy:

Code: 101H

Description: Scanner motor malfunction
• A low motor lock signal is not detected even after the lapse of a predetermined period of time after the scanner motor has been started. • The motor lock signal remains HIGH for a predetermined consecutive period of time while the scanner motor remains energized.
Remedy: 1 Check to see if the lock lever of the Scanner unit is unlocked and unlock the lock lever if it is locked. 2 Check the M5 connector for proper connection and correct as necessary. 3 Check M5 for proper drive coupling and correct as necessary. 4 Check the PRCB connector for proper connection and correct as necessary. 5 M5 operation check. IPB J9IPB-1 to 4 (Pulse Output) L-10. 6 Change PRCB. 7 Change DCPU2. 8 Change DCPU1.

Code: 102H

Description: Faulty ir exposure lamp
• The intensity of the light emitted from the exposure lamp of the scanner falls short of the specified value.
Remedy: 1 Check the exposure lamp for lighting condition when the power switch is turned ON and, if any faulty symptom is evident, correct the Scanner Unit. 2 Check the PRCB connector for proper connection and correct as necessary. 3 Change scanner unit. 4 Change PRCB.