Code: 10H

Description: Polygon motor malfunction
• A low motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started. • The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.

Code: 12H

Description: Laser malfunction
• The SOS signal is not detected within a predetermined period of time after the output of a laser has been started. • The SOS signal is never detected in the image area.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change PRCB.

Code: 14H

Description: 2nd image transfer pressure /retraction failure
• The state of the retraction position sensor/2nd image transfer is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/2nd image transfer is in the unblocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/2nd image transfer is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started. • The retraction position sensor/2nd image transfer is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SD4 connector for proper connection and correct as necessary. 4 Check the PRCB connector for proper connection and correct as necessary. 5 PS5 sensor check. PRCB PJ14PRCB-3 (ON) J to K-3. 6 SD4 operation check. PRCB PJ11PRCB-2 (REM) J to K-1. 7 M1 operation check. PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) C-4. 8 Change PRCB.

Code: 15H

Description: Cleaning blade pressure /retraction failure
• The state of the retraction position sensor/cleaning blade is not changed from the blocked to unblocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/cleaning blade is in the blocked state even after the lapse of a predetermined period of time during predrive. • The retraction position sensor/cleaning blade is not unblocked (blade in the retracted position) within a predetermined period of time after the retraction sequence of the cleaning blade has been started. • The retraction position sensor/cleaning blade is not blocked (blade in the pressed position) within a predetermined period of time after the pressure sequence of the cleaning blade has been started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SD3 connector for proper connection and correct as necessary. 4 Check the PRCB connector for proper connection and correct as necessary. 5 PS6 sensor check. PRCB PJ9PRCB-11 (ON) C-5. 6 SD3 operation check. PRCB PJ10PRCB-5 (REM) C-3. 7 M1 operation check. PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) C-4. 8 Change PRCB.

Code: 16H

Description: Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS4 sensor check. PRCB PJ9PRCB-8 (ON) C-5. 3 Change transfer belt unit. 4 Change PRCB.

Code: 17H

Description: Rack rotation failure
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized. • The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized. • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning. • The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check M2 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 PS3 sensor check. PRCB PJ5PRCB-11 (ON) C-6 5 M2 operation check. PRCB PJ5PRCB-1 to 4 (Pulse Output) C-6 to 7. 6 Change PRCB.

Code: 18H

Description: Heating roller warm-up failure
• The thermistor does not detect a predetermined temperature value even after the lapse of a predetermined period of time after the current warm-up cycle has been started and the current warm-up cycle is thus not completed.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary. 3 Check the lever of the safety switch and correct as necessary. 4 Change the fusing unit. 5 Change PRCB. 6 Change DCPU1.

Code: 19H

Description: Abnormally low heating roller temperature
• The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary. 3 Check the lever of the safety switch and correct as necessary. 4 Change the fusing unit. 5 Change PRCB. 6 Change DCPU1.