Mã lỗi Konica-Minolta Magicolor 2550EN — Trang 3/3
Code:
21
Description: Faulty OHP sensor
• It is determined that the OHP sensor is faulty through a check made at the end of the predrive.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS2 sensor check. 3 Change PRCB.
Code:
24
Description: Faulty fusing thermistor resistor
• The heater lamp remains ON for a predetermined consecutive period of time.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change fusing unit. 3 Change PRCB.
Description: Trouble related to security
• Contact the responsible people of KONICA MINOLTA when not returning in power switch OFF/ON.
Remedy: