Code: 0510

Description: Abnormally low Heating Roller temperature
• The temperature of the Heating Roller Thermistor/1 (TH1) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing. • The temperature of the Heating Roller Thermistor/2 (TH3) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-M. 5 Change PU1.

Code: 0511

Description: Abnormally low Fusing Pressure Roller temperature
• The temperature of the Fusing Pressure Roller Thermistor /1 (TH2) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-M. 5 Change PU1.

Code: 0520

Description: Abnormally high Heating Roller temperature
• The temperatures of the Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) are higher than a given level of degree for 1 second or more uninterruptedly. • The Heater Relay is OFF.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-M. 5 Change PU1.

Code: 0521

Description: Abnormally high Fusing Pressure Roller temperature
• The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts. • The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-M. 5 Change PU1.

Code: 0900

Description: Tray 4 Elevator failure
• The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the connector of M3 for proper drive coupling and correct as necessary. 3 PC7 I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) V-21 to 22. 4 M3 operation check PWB-Z PJ4Z PC-4 to 5 Q-24. 5 Change PWB-Z.

Code: 0910

Description: Tray 3 Elevator failure
• The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the connector of M3 for proper drive coupling and correct as necessary. 3 PC7 I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) V-21 to 22. 4 M3 operation check PWB-Z PJ4Z PC-4 to 5 Q-24. 5 Change PWB-Z.

Code: 0950

Description: Tray 5 Elevator failure
• The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the connector of M3 for proper drive coupling and correct as necessary. 3 PC7 I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) V-21 to 22. 4 M3 operation check PWB-Z PJ4Z PC-4 to 5 Q-24. 5 Change PWB-Z.

Code: 0960

Description: Manual Tray Rise Descent Error
• The Bypass Lift-Up Sensor is not blocked even when the Tray 2 Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the standby position to the feed position was started. • The Bypass Lift-Up Sensor is not unblocked even when the Tray 2 Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the feed position to the standby position was started.
Remedy: 1 Check the M2 connector for proper connection and correct as necessary. 2 Check the connector of M2 for proper drive coupling and correct as necessary. 3 PC14 I/O check, Sensor check PWB-M CNTRY1-10 (ON) C-10. 4 M2 operation check PWB-Z PJ5Z PC-5 to 8 Q-22. 5 Change PWB-Z.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie