Các lỗi thường gặp

Code :
  • Code: A2
  • Description: Fuser temperature is over 210 °C.
    Fuser temperature does not reach 100 °C within 200sec,160 °C within 500sec during warming up, or it is less than 120 °C during standby, and it does not return to set temperature within 100sec after a low temperature error occurred during printing.
  • Causes: High temperature error Temperature rising error error
  • Code: A5
  • Description: 1. Main charger Arc discharge of contact has occurred. 2. DEV,FTR,STR bias Short circuit of contact voltage has occurred.
  • Causes: Charger error
  • Code: A6
  • Description: Fuser/Toner Cartridge fan is not rotating at normal speed.
  • Causes: Fuser/Toner Cartridge fan error
  • Code: A7
  • Description: Power supply fan is not rotating at normal speed.
  • Causes: Power supply fan error
  • Code: A8
  • Description: Ozone fan is not rotating at normal speed.
  • Causes: Ozone fan error
  • Code: A9
  • Description: Multi-Purpose Pickup Roller movement error occurred
  • Causes: Multi-Purpose Pickup Roller movement error
  • Code: AA
  • Description: Toner Cartridge Drive motor (sleeve motor) is not phase-locked and is not rotating at normal speed.
  • Causes: Toner Cartridge Drive motor (sleeve motor) unlocked
  • Code: AB
  • Description: Paper feed motor is not phase-locked and is not rotating at normal speed.
  • Causes: Paper feed motor unlocked error