Mã lỗi Kyocera FS5900C

Code: A2

Description: Fuser temperature is over 210 °C.
Fuser temperature does not reach 100 °C within 200sec,160 °C within 500sec during warming up, or it is less than 120 °C during standby, and it does not return to set temperature within 100sec after a low temperature error occurred during printing.
Causes: High temperature error Temperature rising error error

Code: A5

Description: 1. Main charger Arc discharge of contact has occurred. 2. DEV,FTR,STR bias Short circuit of contact voltage has occurred.
Causes: Charger error

Code: A6

Description: Fuser/Toner Cartridge fan is not rotating at normal speed.
Causes: Fuser/Toner Cartridge fan error

Code: A7

Description: Power supply fan is not rotating at normal speed.
Causes: Power supply fan error

Code: A8

Description: Ozone fan is not rotating at normal speed.
Causes: Ozone fan error

Code: A9

Description: Multi-Purpose Pickup Roller movement error occurred
Causes: Multi-Purpose Pickup Roller movement error

Code: AA

Description: Toner Cartridge Drive motor (sleeve motor) is not phase-locked and is not rotating at normal speed.
Causes: Toner Cartridge Drive motor (sleeve motor) unlocked

Code: AB

Description: Paper feed motor is not phase-locked and is not rotating at normal speed.
Causes: Paper feed motor unlocked error