Description: Fuser unit connector insertion problem Absence of the fuser unit is detected.
Causes: Fuser unit connector inserted incorrectly. Defective fuser unit connector.
Remedy: Fuser unit connector inserted incorrectly. Reinsert the fuser unit connector if necessary. Defective fuser unit connector. Replace the fuser unit.
Causes: Poor contact in the connector terminals. Fuser unit connector inserted incorrectly.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC10 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Fuser unit connector inserted incorrectly. Reinsert the fuser unit connector if necessary.
Description: Developing unit connector insertion problem Absence of the developing unit is detected.
Causes: Developing unit connector inserted incorrectly. Defective developing unit connector.
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Defective developing unit connector. Replace the developing unit.
Description: Broken external thermistor wire The thermistor output value is 4.5 V or more.
Causes: Poor contact in the connector terminals. Defective humidity sensor.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC14 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective humidity sensor. Replace the humidity sensor.
Description: Short-circuited external thermistor The thermistor input value is 0.5 V or less.
Causes: Poor contact in the connector terminals. Defective humidity sensor.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC14 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective humidity sensor. Replace the humidity sensor.
Description: Drum EEPROM error Reading from or writing to EEPROM cannot be performed.
Causes: Poor contact in the connector terminals. Defective drum unit.
Remedy: Poor contact in the connector terminals. Check the connection of connector on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective drum unit. Replace the drum unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.