Các lỗi thường gặp

Code :
  • Code: 2340
  • Description: Fuser pressure release motor time-out error
    When the fuser pressure release motor is driven, the envelope switch (EVSW) is not detectable for 6 s.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser pressure release motor. Defective fuser pressure release motor. Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser pressure release motor and engine PWB (YC38)
    Defective drive transmission system of the fuser pressure release motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective fuser pressure release motor. Replace the fuser pressure release motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2500
  • Description: Paper feed motor error
    The drum motor ready input is not given for 5 s during the paper feed motor is ON.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the paper feed motor. Defective paper feed motor. Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Paper feed motor and engine PWB (YC3)
    Defective drive transmission system of the paper feed motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective paper feed motor. Replace the paper feed motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2600
  • Description: PF paper feed motor error (paper feeder 1)
    The drum motor ready input is not given for 2 s during the PF paper feed motor is ON.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF paper feed motor and PF main PWB (YC6)
    Defective drive transmission system of the PF paper feed motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF paper feed motor. Replace the PF paper feed motor.
    Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 2610
  • Description: PF paper feed motor error (paper feeder 2)
    The drum motor ready input is not given for 2 s during the PF paper feed motor is ON.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF paper feed motor. Defective PF paper feed motor. Defective PF main PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF paper feed motor and PF main PWB (YC6)
    Defective drive transmission system of the PF paper feed motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF paper feed motor. Replace the PF paper feed motor.
    Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
  • Code: 2730
  • Description: Developing release motor error
    When the developing release motor is driven, the motor over-current detection signal is detected continuously for 8 times (800 ms) at 100 ms intervals.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing release motor and engine PWB (YC35)
    Defective drive transmission system of the developing release motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective developing release motor. Replace the developing release motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2740
  • Description: Developing release motor time-out error
    When the developing release motor is driven, the developing release switch (DEVRSW) is not detectable for 1 s.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the developing release motor. Defective developing release motor. Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing release motor and engine PWB (YC35)
    Defective drive transmission system of the developing release motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective developing release motor. Replace the developing release motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 2820
  • Description: Fuser motor error
    The fuser motor ready input is not given for 5 s during the fuser motor is ON.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the fuser motor. Defective fuser motor. Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Fuser motor and engine PWB (YC15)
    Defective drive transmission system of the fuser motor. Check if the rollers and gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective fuser motor. Replace the fuser motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 3100
  • Description: ISU home position error
    The home position is not correct when the power is turned on or at the start of copying using the table.
  • Causes: Defective connector cable or poor contact in the connector. Defective home position sensor. Defective ISU motor. Defective CCD PWB. Defective main PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Home position sensor and CCD PWB (YC3) CCD PWB (YC1) and main PWB (YC8) ISU motor and main PWB (YC36)
    Defective home position sensor. Replace the home position sensor.
    Defective ISU motor. Replace the ISU motor.
    Defective CCD PWB. Replace the scanner unit.
    Defective main PWB. Replace the main PWB and check for correct operation.