Mã lỗi Kyocera FSC2026MFP plus — Trang 9/11

Code: 7402

Description: Developing unit C noninstalling error
No density detection signal is output from toner sensor C in developing unit C.
Causes: Defective connector cable or poor contact in the connector. Defective toner sensor C. Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing unit C and Drum relay PWB (YC10) Drum relay PWB (YC1) and engine PWB (YC34)
Defective toner sensor C. Replace the developing unit C.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 7403

Description: Developing unit M noninstalling error
No density detection signal is output from toner sensor M in developing unit M.
Causes: Defective connector cable or poor contact in the connector. Defective toner sensor M. Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing unit M and Drum relay PWB (YC7) Drum relay PWB (YC1) and engine PWB (YC34)
Defective toner sensor M. Replace the developing unit M.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 7404

Description: Developing unit Y noninstalling error
No density detection signal is output from toner sensor Y in developing unit Y.
Causes: Defective connector cable or poor contact in the connector. Defective toner sensor Y. Defective engine PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developing unit Y and Drum relay PWB (YC13) Drum relay PWB (YC1) and engine PWB (YC34)
Defective toner sensor Y. Replace the developing unit Y.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 7411

Description: Drum unit K non- installing error
The EEPROM of drum PWB K does not communicate normally.
Causes: Installation of incompatible drum unit K. Defective connector cable or poor contact in the connector. Defective drum PWB K. Defective engine PWB.
Remedy: Installation of incompatible drum unit K. Install drum unit K compatible with the specifications to the machine.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit K and Drum relay PWB (YC2) Drum relay PWB (YC1) and engine PWB (YC34)
Defective drum PWB K. Replace the drum unit K.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 7412

Description: Drum unit C non- installing error
The EEPROM of drum PWB C does not communicate normally.
Causes: Installation of incompatible drum unit C. Defective connector cable or poor contact in the connector. Defective drum PWB C. Defective engine PWB.
Remedy: Installation of incompatible drum unit C. Install drum unit C compatible with the specifications to the machine.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit C and Drum relay PWB (YC4) Drum relay PWB (YC1) and engine PWB (YC34)
Defective drum PWB C. Replace the drum unit C.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 7413

Description: Drum unit M non- installing error
The EEPROM of drum PWB M does not communicate normally.
Causes: Installation of incompatible drum unit M. Defective connector cable or poor contact in the connector. Defective drum PWB M. Defective engine PWB.
Remedy: Installation of incompatible drum unit M. Install drum unit M compatible with the specifications to the machine.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit M and Drum relay PWB (YC3) Drum relay PWB (YC1) and engine PWB (YC34)
Defective drum PWB M. Replace the drum unit M.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 7414

Description: Drum unit Y non- installing error
The EEPROM of drum PWB Y does not communicate normally.
Causes: Installation of incompatible drum unit Y. Defective connector cable or poor contact in the connector. Defective drum PWB Y. Defective engine PWB.
Remedy: Installation of incompatible drum unit Y. Install drum unit Y compatible with the specifications to the machine.
Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit Y and Drum relay PWB (YC5) Drum relay PWB (YC1) and engine PWB (YC34)
Defective drum PWB Y. Replace the drum unit Y.
Defective engine PWB. Replace the engine PWB and check for correct operation.

Code: 9500 ... 9520

Description: Contact the Service Administrative Division.
Causes:
Remedy: Contact the Service Administrative Division.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie