Description: Drum motor K startup error Drum motor K is not stabilized within 5 s since the motor is activated.
Causes: Poor contact in the connector terminals. Defective drum motor K. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the motor control PWB and the connector of the drum motor K, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor K. Replace the drum motor K. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2212
Description: Drum motor C startup error Drum motor C is not stabilized within 5 s since the motor is activated.
Causes: Poor contact in the connector terminals. Defective drum motor C. Defective PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the motor control PWB and the connector of the drum motor C, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor C. Replace the drum motor C. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2213
Description: Drum motor M startup error Drum motor M is not stabilized within 5 s since the motor is activated.
Causes: Poor contact in the connector terminals. Defective drum motor M. Defective PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector YC5 on the motor control PWB and the connector of the drum motor M, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor M. Replace the drum motor M. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2214
Description: Drum motor Y startup error Drum motor Y is not stabilized within 5 s since the motor is activated.
Causes: Poor contact in the connector terminals. Defective drum motor Y. Defective PWB
Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the motor control PWB and the connector of the drum motor Y, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor Y. Replace the drum motor Y. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2231
Description: Drum motor K main sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor K. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC8 on the motor control PWB and the connector of the drum motor K, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor K. Replace the drum motor K. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2232
Description: Drum motor C main sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals Defective drum motor C. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC6 on the motor control PWB and the connector of the drum motor C, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor C. Replace the drum motor C. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2233
Description: Drum motor M main sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor M. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC5 on the motor control PWB and the connector of the drum motor M, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor M. Replace the drum motor M. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.
Code: C2234
Description: Drum motor Y main sensor error No signal is input to the sensor for 1.5 s continuously.
Causes: Poor contact in the connector terminals. Defective drum motor Y. Defective PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC7 on the motor control PWB and the connector of the drum motor Y, and the continuity across the connector terminals. Repair or replace if necessary. Defective drum motor Y. Replace the drum motor Y. Defective PWB. Replace the motor control PWB or engine PWB and check for correct operation.