Code: 7810

Description: Short-circuited external thermistor wire
external thermistor delivers 3V or more.
Causes: Defective connector cable or poor contact in the connector. Defective temperature sensor. Defective PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Temperature sensor and engine PWB (YC8)
Defective temperature sensor. Replace the temperature sensor.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7901

Description: Drum unit K EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective drum PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit (K) and drum connect PWB(YC5) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective drum PWB. Replace the drum unit K.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7902

Description: Drum unit C EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective drum PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit (C) and drum connect PWB(YC3) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective drum PWB. Replace the drum unit C.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7903

Description: Drum unit M EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective drum PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit (M) and drum connect PWB(YC4) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective drum PWB. Replace the drum unit M.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7904

Description: Drum unit Y EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective drum PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum unit (Y) and drum connect PWB(YC2) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective drum PWB. Replace the drum unit Y.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7911

Description: Developer unit K EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Defective developer PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit (K) and drum connect PWB(YC9) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective developer PWB. Replace the developer unit K.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7912

Description: Developer unit C EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developer PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit (C) and drum connect PWB(YC7) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective developer PWB. Replace the developer unit C.
Defective PWB. Replace the engine PWB check for correct operation.

Code: 7913

Description: Developer unit M EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developer PWB. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit (M) and drum connect PWB(YC8) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4)
Defective developer PWB. Replace the developer unit M.
Defective PWB. Replace the engine PWB check for correct operation.