Description: Developer unit Y EEPROM error No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively.
Causes: Poor contact in the connector terminals. Defective developer PWB.. Defective PWB.
Remedy: Poor contact in the connector terminals. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit (Y) and drum connect PWB(YC6) drum connect PWB and engine connect PWB (YC8) Engine connect PWB and engine PWB (YC4) Defective developer PWB. Replace the developer unit Y. Defective PWB. Replace the engine PWB check for correct operation.
Code: 8010
Description: Punch motor 1 error When the punch motor is driven, punch home position sensor does not turn on within 200 ms.
Causes: Punch motor. Punch home position sensor. Punch PWB. DF main PWB.
Remedy: Punch motor 1. Execute U240 Motor - Punch to check the finisher operation. 2. Manipulate the punch up and down to check it can smoothly move up and down. 3. Check that the drive from the motor reaches the punch cam. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch motor and Punch PWB (YC4) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the punch motor. Punch home position sensor 1. Execute U241 Punch - Punch HP to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch home position sensor and Punch PWB (YC8) 4. Replace the Punch home position sensor. Punch PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch PWB (YC1) and DF main PWB (YC8) 2. Replace the punch PWB. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
Code: 8020
Description: Punch motor 2 error Home position is not obtained in 3 s after home position is initialized or in standby.
Causes: Punch motor. Punch PWB. DF main PWB.
Remedy: Punch motor 1. Execute U240 Motor - Punch to check the finisher operation. 2. Manipulate the punch up and down to check it can smoothly move up and down. 3. Check that the drive from the motor reaches the punch cam. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch motor and Punch PWB (YC4) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the punch motor. Punch PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch PWB (YC1) and DF main PWB (YC8) 2. Replace the punch PWB. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
Code: 8030
Description: Punch motor 3 error Home position does not turn from On to Off in 50 ms after home position has been initialized.o
Causes: Punch motor. Punch PWB. DF main PWB
Remedy: Punch motor 1. Execute U240 Motor - Punch to check the finisher operation. 2. Manipulate the punch up and down to check it can smoothly move up and down. 3. Check that the drive from the motor reaches the punch cam. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch motor and Punch PWB (YC4) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the punch motor. Punch PWB 1. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. Punch PWB (YC1) and DF main PWB (YC8) 2. Replace the punch PWB. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
Code: 8090
Description: DF paddle motor error When the DF paddle motor is driven, DF paddle sensor does not turn on within 1 s.
Causes: DF paddle motor. DF paddle sensor. DF main PWB.
Remedy: DF paddle motor 1. Execute U240 Motor - Beat to check the finisher operation. 2. Check that the paddle can rotate. 3. Check that the drive from the motor reaches the paddle. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF paddle motor and DF main PWB (YC11) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF paddle motor. DF paddle sensor 1. Execute U241 Finisher - Bundle Eject HP to check the finisher switch. 2. Check that the sensor and its mounting board are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF paddle sensor and DF main PWB (YC20) 4. Replace the DF paddle sensor. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
Code: 8100
Description: DF eject release motor error When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s.
Causes: DF eject release motor DF bundle discharge unit sensor. DF bundle discharge unit sensor. DF main PWB.
Remedy: DF eject release motor DF bundle discharge unit sensor 1. Execute Motor - Eject Unlock (Full) of U240 finisher operation check. 2. Check that the eject guide of the process tray is opened and, if not, correct the guide. 3. Check that the drive from the motor reaches the eject guide. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC20) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF eject release motor. DF bundle discharge unit sensor 1. Execute Finisher - Bundle Eject HP of U241 finisher switch check. 2. Check that the sensor and its mounting board are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF bundle discharge unit sensor and DF main PWB (YC20) 4. Replace the DF bundle discharge unit sensor. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
Code: 8140
Description: DF tray motor error 1 When the main tray has ascended, DF tray sensor 1 or DF tray upper surface sensor does not turn on within 20 s.
Remedy: DF tray motor 1. Execute U240 Motor - Tray to check the finisher operation. 2. Manipulate the main tray up and down to check it is smoothly operable. 3. Check that the drive from the motor reaches the main tray. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF tray motor and DF Main PWB(YC14) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF tray motor. DF tray sensor 1 DF tray upper surface sensor 1. Execute U241 Finisher - Tray U-Limit, Tray Top to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF tray sensor 1 and DF Main DF tray sensor 1 and DF main PWB (YC20) DF tray upper surface sensor and DF main PWB (YC18) 4. Replace the DF tray sensor 1 or DF tray upper surface sensor. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).
Code: 8150
Description: DF tray motor error 2 When the main tray has descended, DF tray sensor 1 or DF tray upper surface sensor does not turn off within 5 s.
Remedy: DF tray motor 1. Execute U240 Motor - Tray to check the finisher operation. 2. Manipulate the main tray up and down to check it is smoothly operable. 3. Check that the drive from the motor reaches the main tray. 4. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF tray motor and DF main PWB (YC14) 5. If the wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the DF tray motor. DF tray sensor 1 DF tray upper surface sensor 1. Execute U241 Finisher - Tray U-Limit, Tray Top to check the finisher switch. 2. Check that the sensor and its mounting bracket are correctly positioned. 3. Confirm that the wiring connector is firmly connected and, if necessary, connect the connector all the way in. DF tray sensor 1 and DF main PWB (YC20) DF tray upper surface sensor and DF main PWB (YC18) 4. Replace the DF tray sensor 1 or DF tray upper surface sensor. DF main PWB Replace the DF main PWB (Refer to the service manual for the document finisher).