Các lỗi thường gặp

Code :
  • Code: 7602
  • Description: ID sensor error
    An abnormal value is detected in the input data to ID sensor.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. ID sensor and relay PWB (YC10) Relay PWB (YC1) and feed PWB 1 (YC14) Feed PWB 1 (YC2) and engine PWB (YC5)
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7800
  • Description: Broken outer temperature sensor wire
    The sensor input sampling is greater than 255.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective outer temperature sensor.
    Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Outer temperature sensor and front PWB (YC8) Front PWB (YC2) and engine PWB (YC8)
    Defective outer temperature sensor. Replace outer temperature sensor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7810
  • Description: Short-circuited outer temperature sensor
    The sensor input sampling is less than 0.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective outer temperature sensor.
    Defective engine PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Outer temperature sensor and front PWB (YC8) Front PWB (YC2) and engine PWB (YC8)
    Defective outer temperature sensor. Replace outer temperature sensor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 7901
  • Description: Drum EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective drum PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Drum PWB and front PWB (YC6) Front PWB (YC2) and engine PWB (YC8)
    Defective drum PWB. Replace the drum unit.
  • Code: 7911
  • Description: Developer unit EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective developer unit.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Developer unit and front PWB (YC7) Front PWB (YC2) and engine PWB (YC8)
    Defective developer unit. Replace the developer unit.
  • Code: 7941
  • Description: Laser scanner unit EEPROM error
    Mismatch of reading data from two locations occurs 8 times successively. Mismatch between writing data and reading data occurs 8 times successively.
  • Causes: Defective connector cable or poor contact in the connector.
    Defective APC PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. APC PWB and LSU relay PWB (YC3) LSU relay PWB (YC2) and engine PWB (YC11)
    Defective APC PWB. Replace the laser scanner unit.
  • Code: 8010
  • Description: Punch motor error 1
    When the punch motor is driven, punch home position sensor does not turn on within 200 ms.
  • Causes: Defective connector cable or poor contact in the connector (4000-sheet finisher).
    Defective connector cable or poor contact in the connector (1000-sheet finisher).
    Defective punch home position sensor.
    Defective punch motor.
    Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector (4000-sheet finisher). Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Punch motor and punch PWB (YC4) Punch home position sensor and punch PWB (YC8) Punch PWB (YC1) and DF main PWB (YC7)
    Defective connector cable or poor contact in the connector (1000-sheet finisher). Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Punch motor and punch PWB (YC4) Punch home position sensor and punch PWB (YC8) Punch PWB (YC1) and DF main PWB (YC8)
    Defective punch home position sensor. Replace the punch home position sensor.
    Defective punch motor. Replace the punch motor.
    Defective PWB. Replace the punch PWB or DF main PWB and check for correct operation.
  • Code: 8020
  • Description: Punch motor error 2
    Home position is not obtained in 3 seconds after home position is initialized or in standby.
  • Causes: Defective connector cable or poor contact in the connector (4000-sheet finisher).
    Defective connector cable or poor contact in the connector (1000-sheet finisher).
    Defective punch motor.
    Defective PWB.
  • Remedy: Defective connector cable or poor contact in the connector (4000-sheet finisher). Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Punch motor and punch PWB (YC4) Punch PWB (YC1) and DF main PWB (YC7)
    Defective connector cable or poor contact in the connector (1000-sheet finisher). Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Punch motor and punch PWB (YC4) Punch PWB (YC1) and DF main PWB (YC8)
    Defective punch motor. Replace the punch motor.
    Defective PWB. Replace the punch PWB or DF main PWB and check for correct operation.
‹ First  < 8 9 10 11 12 13 14 >  Last ›