Các lỗi thường gặp

Code :
  • Code: F101
  • Description: HDD unmounted: Connection of HDD cannot be detected.
  • Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
  • Code: F102
  • Description: HDD start error: HDD cannot become ‘Ready’ state
  • Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
  • Code: F103
  • Description: HDD transfer time-out: Reading/writing cannot be performed in the specified period of time.
  • Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
  • Code: F104
  • Description: HDD data error: Abnormality is detected in the data of HDD.
  • Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
  • Code: F105
  • Description: HDD other error
  • Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.
  • Code: F106
  • Description: Point and Print partition damage
  • Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.
  • Code: F107
  • Description: /BOX partition damage
  • Remedy: Initialize the Electronic Filing using the Setting Mode (08-666).
  • Code: F108
  • Description: /SHA partition damage
  • Remedy: Initialize the shared folder using the Setting Mode (08-667).