Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Kyocera TASKalfa 550c — Trang 39/40

Code: F101

Description: HDD unmounted: Connection of HDD cannot be detected.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.

Code: F102

Description: HDD start error: HDD cannot become ‘Ready’ state
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.

Code: F103

Description: HDD transfer time-out: Reading/writing cannot be performed in the specified period of time.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.

Code: F104

Description: HDD data error: Abnormality is detected in the data of HDD.
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.

Code: F105

Description: HDD other error
Remedy: (1) Check if the connectors of the HDD are disconnected. (2) Check if the connector pins are disconnected or the wires of harnesses are open circuited. (3) Perform the bad sector check (08-694). If the check result is OK, recover the data in the HDD. If the check result is failed, replace the HDD. (4) Replace the SYS board.

Code: F106

Description: Point and Print partition damage
Remedy: (1) Turn the power OFF and start up the Setting Mode (08). (2) Key in “662” and press the [START] button. (Partition clearing is performed.) (3) Restart the equipment. (4) Access TopAccess. Click the [Administration] tab, and then click the Maintenance Menu to open. Then install the “Point and Print” driver.

Code: F107

Description: /BOX partition damage
Remedy: Initialize the Electronic Filing using the Setting Mode (08-666).

Code: F108

Description: /SHA partition damage
Remedy: Initialize the shared folder using the Setting Mode (08-667).