Description: Service NVRAM Failure Mismatch between controller EEPROM and mirror. • 951.00 through 951.29 codes:mismatch between controller and mirror • 951.30 through 951.60: mismatch between secure and controller
Remedy:
Code: 952.xx
Description: Service NVRAM Failure:n A recoverable MVRAM Cyclic Redundancy Check (CRC) erroroccurred. n is the offset at which the error occurred.
Remedy: Performing a POR will clear this error.
Code: 953.xx
Description: Service NVRAM Failure NVRAM chip failure with mirror.
Remedy:
Code: 954.xx
Description: Service NVRAM Failure The NVRAM chip failure with controller part.
Remedy:
Code: 955.xx
Description: Service Code CRC <loc> The Code ROM or NAND flash failed the Cyclic Redundancy Check (CRC)check or the NAND experienced an uncorrectable multi-bit failure. <loc> indicates the source of the failure and has one of the following values: • CRC Failure: The source is a failing package indicated by Pn where n is the package number. This error could occur on a controller with ROM or NAND flash and could occur as a result of the CRC check done when the machine is powered on. The rangeof package numbers is from 0 to 15. • Error Correction Code (ECC)Failure: The source is a failing page indicated by Bn where “n” is the page number. This error occurs only if a multi-bit failure is detectedduring the ECC execution. Single bit failures will be corrected automatically and will not result in a service error. The range of page numbers is from 0 to 1023.
Remedy:
Code: 956.00
Description: Service System Board Controller board failure. Processor failure.
Remedy: Replace the controller board.
Code: 956.01
Description: Service System Board Processor over temperature.
Remedy: Replace the controller board.
Code: 957.xx
Description: Service System Board Controller board failure. ASIC failure.