Remedy: This message is displayed when there is not enough free space on the disk to hold the data that have been requested to be written to the disk. This message is displayed for both resource collection and PostScript when the disk is full. The following actions can be taken, however this deletes all downloaded Fonts and Macros not written to disk. • Press Go to clear the message and continue processing the print job • Press Menu to access the Busy/Waiting Menu The following functions may be available: • Cancel Job • Reset Printer • Reset Active Bin • Check Supply Levels Note: Menu Lockout does NOT prevent access to the Busy/ Waiting Menu.
Code: 63
Description: Unformatted Disk
Remedy: This message is displayed when the printer detects an unformatted disk at POST. Press Go to clear the message. The disk is marked as bad and normal operation continues, however disk operation is not allowed until the disk is formatted.
Code: 64
Description: Unsupported Disk Format
Remedy: This message is displayed when the printer detects an unsupported disk format at POST. This message may appear if the disk was formatted on another system with a different format. Press Go to clear the message. The disk is marked as bad and normal operation continues, however disk operations is not allowed until the disk is formatted.
Code: 80
Description: Fuser Maintenance
Remedy: This messages displays when the printer requires replacement of a worn assembly. The message is independently posted when a fuser needs to be replaced. Press Go to clear this message. See “Scheduled maintenance” for the part number of the maintenance kit. Scheduled maintenance The operator panel displays 80 Fuser Maintenance and 83 ITU Maintenance for scheduled maintenance. 80 Fuser Maintenance is displayed at each 200,000 copies when the fuser assembly needs to be replaced to maintain the print quality and reliability of the printer. The parts are available as a maintenance kit with the following part numbers: Standard fusers • 56P2910, Maintenance kit 115 V fuser • 56P2911, Maintenance kit 220 V fuser • 56P2912, Maintenance kit 100 V fuser Web oiler fusers and web oiler replacements The web oiler fuser has a life of approximately 200,0000 copies, but the web oiler life is about 100,000. • 12G6524, Fuser assembly, web oiler 115 V 500W • 12G6525, Fuser assembly, web oiler 220 V 500W • 12G6499, Fuser assembly, web oiler 100 V 500W (Japan) • 12G6545, Web oiler assembly 83 ITU Maintenance is displayed at each 120,000 copies when the ITU Assembly needs to be replaced to maintain the print quality and reliability of the printer. There are two assemblies, ITU assembly and Second Transfer Roll, in a maintenance kit. Both should be replaced at the same time. The parts are available as a maintenance kit with P/N 56P2848, ITU Maintenance Kit. After replacing the kit, the fuser maintenance count must be reset to zero to clear the maintenance message. 84 Oiler Nearly Exhausted is displayed at each 100,000 copies when the Web Oiler Assembly is nearly exhausted. Go to “Web Oiler Assembly” for part number.
Code: 81
Description: Engine Code CRC Failure
Remedy: This message is displayed when microcode programmed into the engine flash code fails a CRC check. Press Go to clear the message. The code data is discarded and must be resent from the host computer.
Code: 82
Description: Waste Toner Bottle Full
Remedy: This message is displayed when the waste container is full. Replace the waste container and press Go.
Code: 82
Description: Waste Toner Bottle Missing
Remedy: This message is displayed when the waste container is missing. Insert the waste container and press Go.
Code: 83
Description: ITU Maintenance
Remedy: This message displays when the ITU reaches end of life. It is recommended the customer order the maintenance kit. See “Scheduled maintenance” for the part number of the maintenance kit. You can press Go to continue, however, the message persists until replacement. Press Go to clear this message. See “Scheduled maintenance” for the part number of the maintenance kit. Scheduled maintenance The operator panel displays 80 Fuser Maintenance and 83 ITU Maintenance for scheduled maintenance. 80 Fuser Maintenance is displayed at each 200,000 copies when the fuser assembly needs to be replaced to maintain the print quality and reliability of the printer. The parts are available as a maintenance kit with the following part numbers: Standard fusers • 56P2910, Maintenance kit 115 V fuser • 56P2911, Maintenance kit 220 V fuser • 56P2912, Maintenance kit 100 V fuser Web oiler fusers and web oiler replacements The web oiler fuser has a life of approximately 200,0000 copies, but the web oiler life is about 100,000. • 12G6524, Fuser assembly, web oiler 115 V 500W • 12G6525, Fuser assembly, web oiler 220 V 500W • 12G6499, Fuser assembly, web oiler 100 V 500W (Japan) • 12G6545, Web oiler assembly 83 ITU Maintenance is displayed at each 120,000 copies when the ITU Assembly needs to be replaced to maintain the print quality and reliability of the printer. There are two assemblies, ITU assembly and Second Transfer Roll, in a maintenance kit. Both should be replaced at the same time. The parts are available as a maintenance kit with P/N 56P2848, ITU Maintenance Kit. After replacing the kit, the fuser maintenance count must be reset to zero to clear the maintenance message. 84 Oiler Nearly Exhausted is displayed at each 100,000 copies when the Web Oiler Assembly is nearly exhausted. Go to “Web Oiler Assembly” for part number.