Description: •Command code other than MRL has been received.
Remedy: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one. e. Supply power to the 1394 PCI board in the PC through the power cable.
Code: 11
Display: ERROR11 PARAMETER
Description: • Parameter that has not defined in MRL has been received.
Remedy: 1) Check the data received through HEX dump. 2) If error occurs at 1394 a. Check Time out of the transfer tool (RIP). b. Replace the I/F connection board with [E102154A] or later. c. Replace the 1394 board with a new one. d. Replace the main PCB with a new one. e. Supply power to the 1394 PCI board in the PC through the power cable.
Code: 12
Display: ERROR12 Ment Command
Description: •A command error for manufacture of has occurred.
Remedy: 1) It is not used in the field
Code: 20
Display: ERROR20 I/F BOARD
Description: •A error occurred in communication between the main PCB and the interface board.
Remedy: 1) Replace the I/F PCB with a new one. 2) Replace the main PCB with a new one. 3) Replace the I/F connection board with a new one. 4) Supply power to the 1394 PCI board in the PC through the power cable.
Code: 21
Display: ERROR21 I/F NONE
Description: • The I/F board could not be recognized.
Remedy: 1) Is the I/F board mounted correctly?
Code: 23
Display: ERROR23 HOST I/F
Description: •A time limit exceeded error occurred in communication between the host computer and the interface board.
Remedy: 1) Is the cable loose? 2) Has an error occurred on the host computer? 3) Is the application being used running normally?
Code: 24
Display: ERROR24 I/F INITIAL
Description: • The I/F board is in abnormal conditions.
Remedy: 1) Replace the I/F PCBwith a new one. 2) Replace the main PCB with a new one. 3) Replace the main PCB with a new one.