Code :
- Code: E071
- Display: E071 Err PF Current
- Description: An overload condition is detected in PF motor (X-axis) during printer operation.
- Code: E072
- Display: E072 Err CR Current
- Description: An overload condition is detected in CR motor (Y-axis) during printer operation.
- Code: E073
- Display: E073 Err PF2 Current
- Description: An overload condition is detected in PF motor (X-axis) during printer operation.
- Code: E074
- Display: E074 Err CR2 Current
- Description: An overload condition is detected in CR motor (Y-axis) during printer operation.
- Code: E075
- Display: E075 Err Head cable
- Description: An anomaly is detected in Pre heater system (Thermistor, Heater).
- Code: E076
- Display: E076 Err Pre heat
- Description: An anomaly is detected in Pre heater system (Thermistor, Heater).
- Code: E076
- Display: E076 Err Plt. heat
- Description: An anomaly is detected in Platen heater system (Thermistor, Heater).
- Code: E078
- Display: E078 Err After Heat
- Description: An anomaly is detected in After heater system (Thermistor, Heater).