Code :
- Code: E149
- Display: E149 Err Air Heat
- Description: Both Air heater L and Air heater R did not reach the given temperature within the predetermined time after turning Air heater on.
- Code: E150
- Display: E150 Err Air Heat Th.L
- Description: An anomaly is detected in Air heater thermister L.
- Code: E151
- Display: E151 Err Air Heat Th.R
- Description: An anomaly is detected in Air heater thermister R.
- Code: E152
- Display: E152 Err CR Base Fuse